ESTRUCTURAS |
SKR - SKS
| 05-19
SKS EVO
SKR EVO
CÓDIGOS Y DIMENSIONES SKR
EVO - SKS
EVO
d
1
CÓDIGO
L
t
.x
h
1,min
h
nom
d
0
d
f madera
d
f acero
T
inst
unid.
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[Nm]
7,5
SW 13
SKREVO7560
60
10
60
50
6
8
8-10
15
50
10
SW 16
SKREVO1080
80
30
65
50
8
10
10-12
25
50
12
SW 18
SKREVO12100
100
20
100
80
10
12
12-14
50
25
d
1
CÓDIGO
L
t
.x
h
1,min
h
nom
d
0
d
f madera
d
f acero
T
inst
unid.
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[Nm]
7,5
TX 40
SKSEVO7580
80
30
60
50
6
8
-
-
50
SKSEVO75100
100
20
90
80
6
8
-
-
50
SKSEVO75120
120
40
90
80
6
8
-
-
50
DIST
ANCIAS MÍNIMAS SKR -
SKS
DISTANCIAS INTEREJES Y DISTANCIAS PARA CARGAS DE TRACCIÓN
SKR
SKS
Ø
7,5
Ø
10
Ø
12
Ø
7,5
Intereje mínimo
s
min,N
[mm]
50
60
65
50
Distancia mínima desde el borde
c
min,N
[mm]
50
60
65
50
Espesor mínimo del soporte
de hormigón
h
min
[mm]
100
110
130
100
Distancia interejes crítica
s
cr,N
[mm]
100
150
180
100
Distancia crítica desde el borde
c
cr,N
[mm]
50
70
80
50
DISTANCIAS INTEREJES Y DISTANCIAS PARA CARGAS DE CORTE
SKR
SKS
Ø
7,5
Ø
10
Ø
12
Ø
7,5
Intereje mínimo
s
min,V
[mm]
50
60
70
50
Distancia mínima desde el borde
c
min,V
[mm]
50
60
70
50
Espesor mínimo del soporte
de hormigón
h
min
[mm]
100
110
130
100
Distancia interejes crítica
s
cr,V
[mm]
140
200
240
140
Distancia crítica desde el borde
c
cr,V
[mm]
70
110
130
70
Para distancias interejes y distancias menores de las críticas, habrá reducciones en los valores de resistencia a causa de los parámetros de instalación.